GLOSSARY OF TERMS: CALIBRATION

May 2, 2006

ACCURACY: The closeness of an indication or reading of a measurement device to the actual value of the quantity being measured. Usually expressed as ± percent of full scale


ACCURACY: The closeness of an indication or reading of a measurement device to the actual value of the quantity being measured. Usually expressed as ± percent of full scale output or reading.

CFM: The volumetric flow rate of a liquid or gas in cubic feet per minute.

DIFFERENTIAL PRESSURE: The difference in static pressure between two identical pressure taps at the same elevation located in two different locations in a primary device.

ELECTROLYTE: Any substance which, when in solution will conduct an electric current. Acids, bases, and salts are common electrolytes.

FLOWRATE: Actual speed or velocity of fluid movement.

GPM: Volumetric flow rate in gallons per minute.

HEAD LOSS: The loss of pressure in a flow system measured using a length parameter (i.e., inches of water, inches of mercury).

HYSTERESIS: The difference in output when the measurand value is first approached with increasing and then with decreasing values. Expressed in percent of full scale during any one calibration cycle.

KELVIN: Symbol K. The unit of absolute or thermodynamic temperature scale based upon the Celsius scale with 100 units between the ice point and boiling point of water. 0 C = 273.15 K.

LINEARITY: The closeness of a calibration curve to a specified straight line. Linearity is expressed as the maximum deviation of any calibration point on a specified straight line during any one calibration cycle.

MEASURAND: A physical quantity, property, or condition which is measured.

NPT: National Pipe Thread.

POLARITY: In electricity, the quality of having two oppositely charged poles, one positive one negative.

RANGEABILITY: The ratio of the maximum flowrate to the minimum flowrate of a meter.

SENSITIVITY SHIFT: A change in slope of the calibration curve due to a change in sensitivity (i.e., minimum change in input signal to which an instrument can respond).

TRANSITIONAL FLOW: Flow between laminar and turbulent flow, usually between a pipe Reynolds number of 2000 and 4000.

VISCOSITY: The inherent resistance of a substance to flow.

ZERO ADJUSTMENT: The ability to adjust the display of a process or strain meter so that zero on the display corresponds to a non-zero signal, such as 4 mA, 10 mA, or 1 V dc. The adjustment range is normally expressed in counts.

The terms and definitions for this issue’s Word Search come from a glossary compiled by RSHydro (www.rshydro.co.uk), a UK-based consultancy that specializes in flow and level technologies.

Sponsored Recommendations

Learn About: Micro Motion™ 4700 Config I/O Coriolis Transmitter

An Advanced Transmitter that Expands Connectivity

Micro Motion™ G-Series Compact, Drainable Coriolis Flow and Density Meters

Micro Motion G-Series Coriolis flow and density meters are ideally suited for Process Monitoring and Optimization applications, offering easy selection with pre-selected models...

Learn about: Micro Motion G-Series Coriolis Flow and Density Meters

The Micro Motion G-Series is designed to help you access the benefits of Coriolis technology even when available space is limited.

Micro Motion 4700 Coriolis Configurable Inputs and Outputs Transmitter

The Micro Motion 4700 Coriolis Transmitter offers a compact C1D1 (Zone 1) housing. Bluetooth and Smart Meter Verification are available.