Estimating Pump Performance

May 16, 2006

By Ross Mackay, Ross Mackay Associates Not sure what the pump is putting out and can”t find the Pump Performance Curve? So now what do you do? This is

By Ross Mackay, Ross Mackay Associates

Not sure what the pump is putting out and can”t find the Pump Performance Curve?

So now what do you do? This is a fairly common occurrence, particularly with pumps that have been around a long time; possibly since the days that maintenance records weren’t kept as well as they are now.

If you need to know the head the pump is supposed to be developing, the obvious solution is to fit a pressure gauge on the suction and discharge side of the pump at the same elevation, identify the difference, and convert to feet of head. Simple!

However, if you are in one of these plants where gauges appear to be in short supply, there is a Rule of Thumb that will help you approximate the total head being supplied by the pump.

Head = Impeller Diameter Squared

There are, of course, some conditions.

1. The pump must be running at 1,800 RPM.
2. The impeller must be measured in inches.
3. The resulting Head will be in feet.

For example, a 12-inch diameter impeller will provide approximately 144 feet of head when run at 1,800 RPM.

For those of you who will check this, you will note that the result will represent the head somewhere on the performance curve, but not necessarily in the same area. You may even notice that, as the impeller diameter gets larger, i.e., over 10 or 12 inches, the resultant head will move gradually towards the Best Efficiency Point from shutoff.

Obviously, not every pump runs at 1,800 rpm. That’s when the affinity laws help us out.

At 3,600 RPM, the head = four times the impeller diameter squared.
At 1500 RPM, the head = 0.7 times the impeller diameter squared.

This is not just a magic trick that will impress your associates (or maybe even your boss!), it can also be extremely helpful when troubleshooting an operational problem. Frequently, I’ve been able to question a discharge pressure quoted to me when I know the impeller diameter and pump speed, and thereby come to a faster and more accurate solution to the problem.

www.practicalpumping.com

Sponsored Recommendations

Learn About: Micro Motion™ 4700 Config I/O Coriolis Transmitter

An Advanced Transmitter that Expands Connectivity

Micro Motion™ G-Series Compact, Drainable Coriolis Flow and Density Meters

Micro Motion G-Series Coriolis flow and density meters are ideally suited for Process Monitoring and Optimization applications, offering easy selection with pre-selected models...

Learn about: Micro Motion G-Series Coriolis Flow and Density Meters

The Micro Motion G-Series is designed to help you access the benefits of Coriolis technology even when available space is limited.

Micro Motion 4700 Coriolis Configurable Inputs and Outputs Transmitter

The Micro Motion 4700 Coriolis Transmitter offers a compact C1D1 (Zone 1) housing. Bluetooth and Smart Meter Verification are available.