Broadening the Application Base Beyond Semiconductor

Dec. 16, 2013

One important development that is occurring in the mass flow controller market is that a number of companies that supply the semiconductor market are now looking also at industrial applications.

The manufacture of solar panels is an application particularly well suited for mass flow controllers.

Most mass flow controllers employ a thermal principle, but they are not thermal-dispersion flowmeters. Instead, they measure flow by means of a capillary tube. Instead of having the entire fluid pass through the meter body, some of the fluid is diverted through a small capillary tube. This fluid is diverted by creating a small pressure drop in the flow line, which can be done with a laminar flow element. The diverted fluid travels in an inverted U shape until it rejoins the main flowstream.

At the top of the inverted U, two resistance temperature detectors (RTDs) are wrapped around the outside of the capillary tube. Both RTDs are heated. In a condition of no flow, both RTDs have the same signal across them. As flow occurs through the tube, heat is transferred from the upstream RTD to the downstream RTD. This creates a temperature differential between the two RTDs that is proportional to flowrate. The flowmeter electronics sense the difference in signals between the two RTDs, which it uses to create an output signal.

In many ways, the history of mass flow controllers parallels that of thermal flowmeters. Hastings introduced a "thermal air probe" in 1955, which contained small thermocouples in the flowstream. The thermocouples measured the rate of cooling. This device became covered with grime and could not tolerate the heat. As a result, it had to be withdrawn from the market.

Hastings tried again with a capillary tube design, but instead of putting the probe into the flare stack, they put it into a capillary tube that had the temperature sensors on the outside. This was very similar to the design that a mass flow controller uses today to measure flow. When the tube became plugged, it was cleared out with a source of air. This new device was more successful than the earlier version.

While this account highlights some of the successful attempts to develop a mass flow controller, some of the earliest ideas for this type of device go back as far as 1911, when C.C. Thomas described the idea of a flowmeter containing a heated element with two thermometers upstream and downstream of the heated element. This device was never actually produced. In 1947, J. H. Lamb suggested attaching the heater and its thermometers to the outside of the pipe. However, the actual instrument produced gave unstable readings due to velocity profile and other issues.

In addition to Hastings, some sources credit Tylan General with introducing capillary tubes in the 1960s. Other companies were also working on mass flow controllers in the early 1970s. One development involved a micro-machined silicon sensor that had a very fast response time. Therefore, it is difficult to say who was first with the mass flow controller, since several companies were working along similar lines in the late 1960s and early 1970s.

One important development that is occurring in the mass flow controller market is that a number of companies that supply the semiconductor market are now looking also at industrial applications. This doesn’t mean they are abandoning the semiconductor market; instead, they are looking to expand beyond the semiconductor market into the industrial marketplace. The semiconductor market has always been the larger of the two markets, and still is, but it is also notorious for its up and down cycles. MFC companies who expand into industrial markets can help compensate for the cyclical nature of the semiconductor market with applications that are less subject to fluctuation.

Some of the industrial areas that hold promise for mass flow controllers include:

  • Chemical
  • Biotech
  • Pharmaceutical
  • Solar/Photovoltaic
  • Fuel Cells
  • Metals Processing
  • LED Lighting
  • Power

These and other areas are giving new life to the mass flow controller market, and are providing suppliers with additional markets to service outside of semiconductor.

For more information on Flow Research’s work in the area of mass flow controllers, visit FlowMFC.com.

About the Author

Jesse Yoder

Jesse Yoder, Ph.D., is president of Flow Research Inc. He has 30 years of experience as an analyst and writer in instrumentation. Yoder holds two U.S. patents on a dual-tube meter design and is the author of "The Tao of Measurement," published by ISA. He may be reached at [email protected]. Find more information on the latest study from Flow Research, "The World Market for Gas Flow Measurement, 4th Edition," at www.gasflows.com.

Sponsored Recommendations

Learn About: Micro Motion™ 4700 Config I/O Coriolis Transmitter

An Advanced Transmitter that Expands Connectivity

Micro Motion™ G-Series Compact, Drainable Coriolis Flow and Density Meters

Micro Motion G-Series Coriolis flow and density meters are ideally suited for Process Monitoring and Optimization applications, offering easy selection with pre-selected models...

Learn about: Micro Motion G-Series Coriolis Flow and Density Meters

The Micro Motion G-Series is designed to help you access the benefits of Coriolis technology even when available space is limited.

Micro Motion 4700 Coriolis Configurable Inputs and Outputs Transmitter

The Micro Motion 4700 Coriolis Transmitter offers a compact C1D1 (Zone 1) housing. Bluetooth and Smart Meter Verification are available.